9031561 E1 Application Views
4-27
Centillion Common Application
FDB Group
IF Extensions (Application View)
This view contains the same information as the IF Extensions Configuration
view in Chapter 3, Configuration Views.
TR IF Extensions
This table contains Token Ring interface parameters and state variables, one
entry per 802.5 interface.
IF Index
The value of this object identifies the 802.5 interface for which this entry
contains management information. The value of this object for a particular
interface has the same value as the ifIndex object.
Port Connection Type
The type of connection used on this port. Setting a value to this object requires
the port to be reset and re-opened before taking effect. Allowable connections
are: Station - (default) the port is configured as a standard ring station,
Ring-In/Ring-Out - the port is connected to the Ring-In or Ring-Out port of
a MAU with an appropriate cable. DTR - the port has a direct connection to a
ring station.
Port Speed Sense
Indicates whether speed sensing is enabled (default), or disabled on the port.
This is used in conjunction with the RingSpeed to either match or force the
configured speed.
Admin Ring Sense
The configured ring speed of the port. The speed will take effect on the next
opening of the ring.
FDB Group
This table contains FDB information for each station known to the system,
one entry per station. Static stations may be created by specifying the
stationAddress, stationCard and stationPort. Entries may be
subsequently modified by setting the appropriate object for the entry. Entries
are deleted by clearing stationInUse.
Remote Aging Timer
The timeout period, in seconds, for aging out dynamically learned remote (off-
ring) stations. The default value is 300 seconds.
Table Flush
When read, this object returns a zero length string. If set, the octets describe
which stations to flush. All 4 octets must be specified. The encoding of the
octet string is as follows: