Bay Networks 5391 Guide d'installation Page 94

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 138
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 93
Remote Annex 6300 Hardware Installation Guide
Chapter 4 Troubleshooting Procedures
4-6
Activity N2: Testing
the Hardware
During the power-up sequence, the Remote Annex 6300 runs a series
of self-test diagnostics. These diagnostics test internal hardware
functions. If a test fails, the ATTN and STAT LEDs flash and an error
message is displayed on the console port. The Ethernet LED (Link
LED) lights for a few seconds, then the TRAF LED flashes during the
power-up self-tests. After the self-tests complete, only the STAT and
Ethernet Link LED remain on.
Normal Mode Error Sequence
Table 4-3 shows the state of the LEDs when an error occurs at various
stages of the start-up process. If the Remote Annex 6300 fails during
the hardware-test state (N2), the error condition is hardware failure
NE2. A description of possible causes and solutions for each error
condition is in the following paragraphs.
Table 4-3. Normal Mode Error LED States
Key:
On continuously.
Off.
Flashing irregularly.
Flashing regularly (about 1Hz).
Activity NE2:
Hardware Failure
The ROM diagnostics detected a Remote Annex 6300 hardware
problem requiring service; call Technical Support.
Activity
STAT
Green
ATTN
Amber
TRAF
Green
NE2: Hardware Failure
NE5: Booted wrong image